Shear Connector Studs are designed to tie concrete to the steel beams and to reisist shear loadings between the concrete slab and steel beam in composite construction.

Length is before weld. Stud when welded to base metal will be approximately 3/16” shorter after weld and when welded thru-deck 3/8” shorter after weld. Lengths for shear connector studs are generally set by governing specifications. Consult your NFS representative for other available lengths for specific applications. Made to order lengths available upon request.

Material – Low carbon steel, ASTM A108 1010-1020.  Shear connector studs are also available in stainless steel.

Shear Connector

Clear
Part Number: N/A Categories: ,

Description

Stud Specifications
Stud Diameter (D) Stud Standard Length (L) Part Number 1000 Pieces Weight (lbs) Pieces Per Box
1 4 1/4 SC 100-0425 1079 50
5 1/4 SC 100-0525 1302 50
6 1/4 SC 100-0625 1514 40
8 1/4 SC 100-0825 1978 85
9 1/4 SC 100-0925 2193 50
10 1/4 SC 100-1025 2475 35

Special sizes available upon request

 

Mechanical Property Requirements
Type A* Type B**
Tensile Strength 61,000 psi minimum 65,000 psi minimum
(420 MPa) (450 MPa)
Yield Strength (0.2% offset) 49,000 psi minimum 51,000 psi minimum
(340 MPa) (350 MPa)
Elongation (% in 2 in.) 17% min 20% min
Elongation (% in 5x dia.) 14% min 15% min
Reduction of Area 50% min 50% min

* Type A shall be general purpose of any type and size used for purposes other than shear transfer in composite beam design and construction.

** Type B shall be studs that are headed, bent, or of other configuration in 1/2 in. (12.7 mm), 3/4 in. (19 mm), 7/8 in. (22.2 mm), and 1 in. (25.4 mm) diameter that are used as an essential component in composite beam design and construction.